Fresh Air Hose Devices are self-contained breathing apparatuses and are predominantly used in contaminated or low-oxygen working areas where the use of normal filter respiratory protection is not possible or where a supply of breathing air via compressed air cannot be established.
The e-breathe fresh air pressure hose device supports the breathing of the wearer using a powered air respiratory and thereby relieves the wearer.
The PAPR is positioned and fixed at the end of the hose in an area free of respiratory toxins. The blower leads the breathable air via the connected breathing tube into the full mask of the wearer. This ensures that the full face mask is constantly supplied with an overpressure of breathable air.
Full Face Mask:
Different full masks are available according to the user‘s requirements.
Breathing Air Hose:
Breathing air hose with round thread connection according to EN148-1 for full face masks with round thread connection.
Multifunctional application options:
In areas where filtering respiratory protection can be used, only the full mask with a respiratory filter can be used as an alternative. For this purpose, the filter is screwed directly into the full face mask. Another alternative would be to use the full face mask with the enclosed e-Flow as a blower filter system. For this you need a separately available blower belt and a breathing air hose for the direct connection of the blower with the full mask. With only one system, the user can switch between an ambient independent isolating device or an ambient dependent filter breathing device, depending on the field of application.
Belt:
Leather belt with freely rotatable quick coupling from the spiral hose to the breathing hose. Optional accessories: textile belt and decon belt.
Air Supply Hose:
The robust and very flexible plastic spiral hose is available in four different lengths (10, 20, 30 or 40m).
Pressure Relief Valve:
A pressure relief valve is attached to the blower to ensure a constant airflow to the carrier.
PAPR:
Operated by the powerful „e-breathe e-Flow“ respiratory protection blower with two e-breathe P3 R / PSL particle filters. With additional accessories (belt & breathing hose), the blower can also be used as a filter device for stall, plant protection or disinfection work.
Ground Anchor:
Robust ground anchor for safe fixation of the blower in a safe area.
e-breathe Supplied AIr Respirator (FDS) EN 138 Class 2
– PAPR EN 12941 / EN 12942
– Particlefilter EN 12941 / EN 12942 / EN 143 P3 R / PSL
– Full Face Mask EN 136 Class 3 / EN 12942
Protection Class:
1000
Airflow:
Adjustable on the device in three stages:
120 – 140 – 160 l/min Full Mask System
Airflow Warning:
< 120 l/min Full Mask System
Battery Warning:
< 15 min remaining time
Battery:
Lithium-Ion Battery: 14,4V / 3,4Ah / 49WH
Operating Time:
approx. 8 to 10 hours
(Depends on the concentration of pollutants and the adjusted airflow.)
Battery Recharging Time:
2,5 hours
Weight:
approx. 1100g (with battery / without filters / without belt)
Temperature Range:
-10°C to +40°C <70% RH
Alarm System:
optical alarm (Display of the alarm at the color display with corresponding error code.)
acoustic alarm (≥ 75 dB )
vibration alarm
Fresh Air Hose Devices are self-contained breathing apparatuses and are predominantly used in contaminated or low-oxygen working areas where the use of normal filter respiratory protection is not possible or where a supply of breathing air via compressed air cannot be established.
The e-breathe fresh air pressure hose device supports the breathing of the wearer using a powered air respiratory and thereby relieves the wearer.
The PAPR is positioned and fixed at the end of the hose in an area free of respiratory toxins. The blower leads the breathable air via the connected breathing tube into the full mask of the wearer. This ensures that the full face mask is constantly supplied with an overpressure of breathable air.
Full Face Mask:
Different full masks are available according to the user‘s requirements.
Breathing Air Hose:
Breathing air hose with round thread connection according to EN148-1 for full face masks with round thread connection.
Multifunctional application options:
In areas where filtering respiratory protection can be used, only the full mask with a respiratory filter can be used as an alternative. For this purpose, the filter is screwed directly into the full face mask. Another alternative would be to use the full face mask with the enclosed e-Flow as a blower filter system. For this you need a separately available blower belt and a breathing air hose for the direct connection of the blower with the full mask. With only one system, the user can switch between an ambient independent isolating device or an ambient dependent filter breathing device, depending on the field of application.
Belt:
Leather belt with freely rotatable quick coupling from the spiral hose to the breathing hose. Optional accessories: textile belt and decon belt.
Air Supply Hose:
The robust and very flexible plastic spiral hose is available in four different lengths (10, 20, 30 or 40m).
Pressure Relief Valve:
A pressure relief valve is attached to the blower to ensure a constant airflow to the carrier.
PAPR:
Operated by the powerful „e-breathe e-Flow“ respiratory protection blower with two e-breathe P3 R / PSL particle filters. With additional accessories (belt & breathing hose), the blower can also be used as a filter device for stall, plant protection or disinfection work.
Ground Anchor:
Robust ground anchor for safe fixation of the blower in a safe area.
Technical Specifications
– PAPR EN 12941 / EN 12942
– Particlefilter EN 12941 / EN 12942 / EN 143 P3 R / PSL
– Full Face Mask EN 136 Class 3 / EN 12942
120 – 140 – 160 l/min Full Mask System
(Depends on the concentration of pollutants and the adjusted airflow.)
acoustic alarm (≥ 75 dB )
vibration alarm